CyberPower PR5000ELCDRTXL5U, Line-Interactive, 5 kVA, 4000 W, Sine, 159 V, 288 V

Operating temperature (T-T): 0 - 40 °CWaveform: SineOutput frequency regulation: 50/60 HzAutomatic Voltage Regulation (AVR): YesSerial interface type: RS-232Number of batteries supported: 16

Specifikacije

Operating temperature (T-T)
0 - 40 °C
Waveform
Sine
Output frequency regulation
50/60 Hz
Automatic Voltage Regulation (AVR)
Yes
Serial interface type
RS-232

Opis

CyberPower PR5000ELCDRTXL5U Line-Interactive UPS, with seamless Pure Sine Wave, provides the best power protection available for office system devices including PCs, workstations, networking devices, and peripherals. It’s typically integrated in the back office, server room, and data center environment. The rackmount / tower convertible design gives it enhanced flexibility for installation and operation in almost any environment.

Multiple UPS systems can be connected to a single main Emergency Power Off (EPO) switch. In the event of an emergency, the UPS systems can be shut down immediately with the EPO button. As for battery maintenance, the UPS allows battery hot-swapping, which enables users to perform normal battery maintenance without significant interruption.

Features

- Energy Saving Technology
- Active PFC Compatible
- Pure Sine Wave Output
- Automatic Voltage Regulation (AVR)
- Overload Protection
- Critical/ Non-critical Load Outlets
- Hot-swappable Battery Packs
- External Battery Module (EBM)
- Surge and Spike Protection
- EMI and RFI Filtration
- Phone/ Fax/ Modem/ DSL/ Network Protection
- LCD Status Display
- USB Connectivity Port
- Serial Connectivity Port
- Emergency Power Off (EPO) Port
- PowerPanel® Management Software
- SNMP/ HTTP Remote Management Capability
- Rack/ Tower Convertible Configurations

Emergency Power Off

The emergency power off is used to immediately power down the UPS in order to terminate its output power in case of a disaster, for example during a building fire. Multiple UPS systems can be connected to a single access point, and by manually activating it can immediately shutdown all the UPS systems to ensure rescue personnel safety.

Critical/Noncritical Load Outlets

By dividing the outlets according to the importance of the connected loads, users are offered the flexibility to wisely manage the limited battery power during the event of power outage. In the state of a power failure, the UPS battery power can be preserve by terminating the power provided to the non-critical outlets, sparing the power to allow more runtime for critical loads to perform graceful shutdown.